Explore our core pre-engineered and custom manufactured water purification platforms. Each skid undergoes stringent hydrostatic, electrical, and performance Factory Acceptance Testing (FAT) prior to shipment.
Industrial water purification has evolved from simple mineral deionization into a mission-critical baseline for high-precision manufacturing. Modern manufacturing plants demand absolute microbiological control, ionic stability, and full regulatory traceability.
Global pharmaceutical and high-tech manufacturing requires water systems that align precisely with regional pharmacopeias (USP, Ph. Eur., JP, ChP) alongside statutory safety certifications. A CE-marked purified water skid verifies full compliance with the European Machinery Directive (2006/42/EC), Low Voltage Directive (2014/35/EU), and Electromagnetic Compatibility (2014/30/EU), mitigating non-compliance risks during commercial operation.
High-purity systems operating under hydraulic or pneumatic pressures exceeding 0.5 bar must comply with PED 2014/68/EU. As a direct manufacturer, our manufacturing process incorporates certified pressure vessels, ASME BPE-compliant 316L stainless steel hygienic pipe loops, pneumatic angle-seat valves, and documented hydrostatic rupture tests executed in strict accordance with harmonized European standards.
Traditional chemical ion-exchange regeneration using hazardous acid (HCl) and caustic (NaOH) reagents is obsolete in modern industrial facilities. Our systems feature continuous electrodeionization (EDI) polishing stages that apply electric current across selective ion-exchange membranes, achieving constant 15–18.2 MΩ·cm resistivity with zero chemical wastewater discharge.
In sterile manufacturing, pharmaceutical processing, and high-density semiconductor fabrication, water is categorized as an active raw material. Our CE-certified purified water skids integrate automated SCADA/PLC architectures with audit trail integrity conforming to 21 CFR Part 11, enabling real-time logging of Total Organic Carbon (TOC), electrolytic conductivity, dissolved ozone, operating pressure, and flow rates.
Biofilm formation within distribution loops is the primary failure mode of industrial purified water systems. Our engineering methodology eliminates mechanical dead zones through precision orbital welding, stringent surface finishes, and periodic thermal sanitization.
Our piping network adheres strictly to ASME Bioprocessing Equipment (BPE) guidelines, maintaining the length-to-diameter ratio of any branch or instrument port below 1.5D to 3D. This hydraulic profile prevents fluid stagnation, eliminating microscopic niches where bio-adhesion, sessile bacteria, and micro-colonization can initiate.
All wetted surfaces, pump casings, storage vessels, and valve manifolds utilize AISI 316L austenitic stainless steel. Component interiors are mechanical-ground followed by electrochemical polishing (EP) to an absolute roughness profile of Ra ≤ 0.4 μm (16 μin), verified via certified profilometer inspections and passivation logs.
Chemical biocides leave trace halogenated residues that compromise ultra-clean processes. Our skids utilize fully automated thermal self-sanitization loops with heat exchangers bringing water to 80–85°C, sustaining recirculation across the loop to achieve reliable pasteurization and endotoxin breakdown without introducing foreign reagents.
For operations requiring continuous ambient disinfection, our skids incorporate electrolytic or corona-discharge ozone injection (20–50 ppb residual) paired with 254 nm germicidal UV destruction reactors, reducing dissolved ozone to undetectable levels (<1 ppb) before distribution to points of use.
| Performance Parameter | Single-Pass RO + Mixed Bed | Double-Pass RO + CEDI | Ultrafiltration + Two-Stage RO + CEDI + UV (Tongjie Standard) |
|---|---|---|---|
| Product Conductivity (25°C) | ≤ 1.0 μS/cm (Unstable over time) | ≤ 0.1 μS/cm (10.0 MΩ·cm) | ≤ 0.055 μS/cm (18.2 MΩ·cm Resistivity) |
| Total Organic Carbon (TOC) | < 200 ppb | < 50 ppb | < 5 – 10 ppb (Real-Time Monitored) |
| Microbial Endotoxins | < 0.5 EU/ml | < 0.25 EU/ml | < 0.03 EU/ml (Ph. Eur. / USP Compliant) |
| Regeneration Waste Stream | Hazardous Acid/Base Salt Brine | Zero Chemicals; Continuous Bleed | Zero Chemicals; Permeate Recycled to Feed |
| EU CE & PED Documentation | Often Limited / Fragmented | Standard Declarations | Full PED Module B+D, 3.1 MTRs, 21 CFR Part 11 |
| Operational Downtime | 4–8 hrs per regeneration cycle | Minimal (Semi-continuous) | Zero Downtime (Continuous Self-Regenerative) |
Procuring capital equipment from overseas requires certainty that delivered skids interface seamlessly with local electrical grids, site utilities, and regional regulatory frameworks across Europe, North America, the Middle East, and Southeast Asia.
We build our control panels to conform to EN 60204-1 safety standards. We support native 380V/400V/415V 50Hz (EU, UK, Asia, Middle East) and 460V/480V 60Hz (North American UL 508A configurations). All components, including VFDs, contactors, and circuit breakers, are sourced from Schneider, Siemens, or ABB with international warranty support.
Every system includes a comprehensive engineering handover package: Design Qualification (DQ), Installation Qualification (IQ), Operational Qualification (OQ), and support for Performance Qualification (PQ). This covers EN 10204 3.1 material certificates, boroscope weld inspection videos, surface roughness certificates, calibration reports, and functional test records.
Field assembly bottlenecks are minimized. Our purified water units arrive as self-contained, pre-wired, and pressure-tested skid systems or ISO-containerized modules. Once positioned on the factory floor, operators connect the raw water feed, permeate outlet, concentrated drain, and power supply, achieving water production in 3 to 7 working days.
Our CE-certified purified water systems serve as the core purification infrastructure across varied manufacturing sectors with distinct water quality thresholds.
Delivering high-purity water meeting United States Pharmacopeia (USP) and European Pharmacopoeia (Ph. Eur.) standards. Crucial for active pharmaceutical ingredients (APIs), biological fermentation feeds, parenteral reconstitution, vial washing, and Clean-In-Place (CIP) systems with full microbiological traceability.
Advanced electronics require ultra-pure water (UPW) compliant with ASTM D5127 Type E-1 standards. Our multi-stage RO, degasification, and EDI trains eliminate trace boron, reactive silica, particles down to 0.05 μm, and dissolved ionic impurities to prevent short-circuits during wafer slicing, etching, and chip-cleaning processes.
Mineral impurities and heavy metals can trigger emulsion breakdown, scent degradation, and microbial spoilage. Our systems provide stable demineralized water with low surface tension and zero bacterial contamination, ensuring consistent batch stability and extended product shelf life.
Operating superheated steam turbines requires demineralized water with silica levels below 10 ppb to prevent scale deposition on turbine blades. Our systems integrate twin-pass RO and EDI, reducing downtime and lowering thermal blowdown energy losses.
Ingredient blending, infant formula, and beverage brewing require high-purity water free from chlorine, pesticides, trihalomethanes (THMs), and off-flavors. Our skids utilize sanitary, food-contact grade elastomers compliant with FDA CFR 177.2600 and EU Regulation 1935/2004.
Lithium-ion cathode material synthesis and electrolyte production require water free of sodium, calcium, and chloride ions. Our high-efficiency systems maintain stable conductivity (<0.1 μS/cm), protecting chemical purity and battery energy densities.
Purified water manufacturing is advancing through integrated digital intelligence, automated self-tuning hydraulic models, and industrial Internet of Things (IIoT) telemetry.
Our control packages feature Siemens S7-1500 or Allen-Bradley ControlLogix PLCs integrated with edge computing gateways. Real-time data streams for normalized permeate flux, differential pressures (ΔP), and recovery ratios are evaluated through algorithmic models to detect membrane scaling or compaction before water quality is impacted.
Standard systems often experience premature membrane foul-up due to erratic permeate draw and manual throttling. Our variable-frequency drive (VFD) pressure arrays continuously adjust feed pressure based on temperature-corrected flux profiles, reducing pump kilowatt draw by up to 28% and extending RO membrane service intervals.
Traditional agar plate incubation requires 48 to 72 hours, delaying corrective action during contamination events. Our advanced validation skids can be configured with real-time laser-induced fluorescence or flow cytometric bio-sensors that count viable microbial cells instantly, enabling immediate, automated thermal sanitization cycles.
In addition to standard purified water skids, we design and manufacture specialized zero-liquid-discharge (ZLD), high-salinity separation, and containerized mobile systems for industrial plants worldwide.
Direct technical responses addressing common engineering questions encountered by procurement managers, process engineers, and validation professionals when specifying purified water systems.
Prior to sea-freight packing, every skid undergo a full wet FAT at our Shanghai manufacturing facility. Clients and EPC contractors can inspect via on-site witnessing or multi-camera high-definition remote streaming.
Loop piping, filter housings, and membrane pressure vessels undergo 1.5× design working pressure hydrostatic holds for 60 continuous minutes without measurable pressure drops. Clean air/helium sniffer testing confirms zero atmospheric infiltration across hygienic flange couplings.
We execute 100% visual inspection and a minimum 20% internal digital video boroscope inspection on all automated orbital welds. Handover documentation includes raw video footage verifying full root-pass penetration, absence of concavity, and clean passivation halos per AWS D18.1/D18.2 criteria.
Emergency stop procedures, high-pressure pump trips, high-conductivity diversion bypass loops, thermal sanitization hold timers, and analog sensor loop calibrations are simulated and verified before skid disassembly and export packaging.